HI-97745C multiparameterfotometerkit – fritt og totalt klor, total hardhet, jern og pH
HI-97745C multiparameterfotometerkit – fritt og totalt klor, total hardhet, jern og pH
Skynd deg, kun 1 vare igjen på lager.
The HI-97745C is a portable multiparameter photometer designed for comprehensive water quality testing. It measures pH, free and total chlorine, magnesium hardness, calcium hardness, total hardness and low-range iron, making it suitable for drinking water, swimming pools, wastewater and general water treatment applications.
Its advanced optical system uses an LED light source and a narrow-band interference filter to deliver accurate and repeatable results. The built-in CAL Check™ function allows users to verify instrument performance using certified standards, while the guided tutorial helps simplify sample preparation and testing procedures.
The photometer features an IP67-rated waterproof housing that floats if accidentally dropped into water. With automatic data logging for up to 50 readings and a backlit display, it is well suited to both field measurements and laboratory use.
The HI-97745C kit includes CAL Check™ standards for all supported measurement parameters.
Couldn't load pickup availability
Beskrivelse
Beskrivelse
HI-97745C multiparameter-fotometerkit – fritt og totalt klor, total hardhet, jern og pH
Spesifikasjoner
Spesifikasjoner
| Measurement Specifications | ||
| pH Range | 6.5 to 8.5 pH | |
| pH Resolution | 0.1 pH | |
| pH Accuracy | ±0.1 pH of reading at 25°C | |
| Free Chlorine Range | 0.00 to 5.00 mg/L (ppm) as Cl₂ | |
| Total Chlorine Range | 0.00 to 5.00 mg/L (ppm) as Cl₂ | |
| Chlorine Resolution | 0.01 mg/L | |
| Chlorine Accuracy | ±0.03 mg/L ±3% of reading at 25°C | |
| Magnesium Hardness Range | 0.00 to 2.00 mg/L as CaCO₃ | |
| Calcium Hardness Range | 0.00 to 2.70 mg/L as CaCO₃ | |
| Total Hardness Range | 0.00 to 4.70 mg/L as CaCO₃ | |
| Hardness Resolution | 0.01 mg/L | |
| Hardness Accuracy | ±0.11 mg/L ±5% of reading at 25°C | |
| Iron Low Range | 0.00 to 1.60 mg/L (ppm) as Fe | |
| Iron Resolution | 0.01 mg/L | |
| Iron Accuracy | ±0.01 mg/L ±8% of reading at 25°C | |
| Measurement Methods | ||
| pH Method | Adaptation of the Phenol Red Method | |
| Chlorine Method | Adaptation of US EPA Method 330.5, DPD Colorimetric Method | |
| Hardness Method | Adaptation of Standard Methods for the Examination of Water and Wastewater, 18th Edition | |
| Iron Method | Adaptation of the TPTZ Method | |
| Optical System | ||
| Light Source | LED | |
| Wavelength | 525 nm | |
| Bandpass Filter Bandwidth | 8 nm | |
| Wavelength Accuracy | ±1.0 nm | |
| Light Detector | Silicon photocell | |
| Cuvette Type | Round, 24.6 mm diameter (22 mm inside) | |
| Functions and Data Management | ||
| CAL Check™ | Yes, using certified CAL Check™ standards | |
| Data Logging | 50 readings | |
| Display | 128 × 64 pixel backlit black-and-white LCD | |
| Guided Tutorial | Yes | |
| Auto-Off | After 15 minutes of inactivity; 30 minutes before a READ measurement | |
| General Specifications | ||
| Waterproof Rating | IP67, floating housing | |
| Battery Type | 3 × 1.5 V AA alkaline batteries | |
| Battery Life | More than 800 measurements without backlight | |
| Operating Environment | 0 to 50°C; 0 to 100% RH, non-serviceable | |
| Dimensions | 142.5 × 102.5 × 50.5 mm | |
| Weight | 380 g with batteries | |
| Warranty | 2 years | |