HI-97115C MARINE MASTER WATERPROOF WIRELESS MULTIPARAMETER PHOTOMETER KIT
HI-97115C MARINE MASTER WATERPROOF WIRELESS MULTIPARAMETER PHOTOMETER KIT
Prisen er ekskl. mva.
Skynd deg, kun 2 vare igjen på lager.
A great kit comprising a compact and versatile Marine multiparameter photometer designed to accurately determine the eight parameters listed. It is suitable for use in the field or Lab/benchtop environments. *The lead image of the kit is for illustration purposes only. Contents of the kit may differ from other photometers in the series.
Couldn't load pickup availability
Beskrivelse
Beskrivelse
Spesifikasjoner
Spesifikasjoner
| Alkalinity, Marine Range | 0.0 to 20.0 dkH 0 to 357 ppm (as CaCo3) | |
| Alkalinity, Marine Resolution | 0.1 dkH | |
| Alkalinity, Marine Accuracy | ±0.3 dKH ±5 % of reading at 25 °C ±5 ppm ±5 % of reading at 25 °C | |
| Alkalinity, Marine Method | Colorimetric Method - The reaction causes a distinctive range of colours from yellow to greenish blue to develop | |
| Ammonia, Marine Range | 0.00 to 2.50 ppm (as NH₃) | |
| Ammonia, Marine Resolution | 0.01 ppm | |
| Ammonia, Marine Accuracy | ±0.05 ppm ±5% of reading at 25°C | |
| Ammonia, Marine Method | Adaptation of the Salicylate Method | |
| Ammonia, Marine LED | 610 nm | |
| Calcium, Marine Range | 200 to 600 ppm | |
| Calcium, Marine Resolution | 1 ppm | |
| Calcium, Marine Accuracy | ±6 % of reading at 25 °C | |
| Calcium, Marine Method | Adaptation of the Zincon Method | |
| LED | 610nm | |
| Marine Magnesium | ||
| Range | 1000 to 1800 ppm (as Mg2+) | |
| Resolution | 5 ppm | |
| Accuracy | ±5% of reading at 25 °C | |
| Method | Adaptation of the Colorimetric EDTA Method using calmagite indicator | |
| LED | 610 nm | |
| Nitrate Range | 0.00 to 5.00 ppm (as No3¯) 0.0 to 75.0 ppm (as No3¯) | |
| Nitrate Resolution | 0.01 ppm | |
| Nitrate Accuracy | ±0.25 ppm ±2% of reading at 25°C | |
| Nitrate Method | Zinc reduction method | |
| LED | 525nm | |
| Nitrite, Marine ULR Range | 0 to 200 ppb (as No2¯-N) | |
| Nitrite, Marine ULR Resolution | 1 ppb | |
| Nitrite, Marine ULR Accuracy | ±10 ppb ±4 % of reading at 25 °C | |
| Nitrite, Marine ULR Method | Adaptation of the EPA Diazotization Method 354.1 - The reaction between nitrite and the reagent causes a pink tint in the sample. | |
| LED | 525nm | |
| Marine pH Range | 6.3 to 8.6 pH | |
| pH Resolution | 0.1 pH | |
| pH Accuracy | ±0.2 pH of reading at 25°C | |
| pH Method | Colorimetric Adaptation of the Phenol Red Method | |
| LED | 525nm | |
| Phosphate, ULR Range | 0.00 to 0.90 ppm | |
| Phosphate, ULR Resolution | 0.01 ppm | |
| Phosphate, ULR Accuracy | ±0.02 ppm ±5 % of reading at 25 °C | |
| Phosphate, ULR Method | Adaptation of Standard Methods for the Examination of Water and Wastewater, 20th Edition, Ascorbic Acid Method - The reaction between phosphate and the reagent causes a blue tint in the sample. | |
| LED | 610nm | |
| Light Source | light emitting diode (LED) | |
| Light Detector | Silicon photocell | |
| Bandpass Filter Bandwidth | 8 nm | |
| Bandpass Filter Wavelength Accuracy | ±1.0 nm | |
| Logging | 200 readings | |
| Power Supply | 1.5 V AA Alkaline (3 pcs.) | |
| Battery Life | > 800 measurements (without backlight) | |
| Auto-off | After 15 minutes of inactivity | |
| Environment | 0 to 50 °C (32 to 122 °F); 0 to 100% RH, non serviceable | |
| Dimensions | 142.5 x 102.5 x 50.5 mm (5.6 x 4.0 x 2.0") | |
| Weight | 380 g (13.4 oz.); with batteries | |
| Casing | IP67 rated, floats | |
| Warranty | 2 years |
| Reagents, CAL Check Standards & accessories - buy separately: |
| Reagent sets | |
| HI-758‑26 | Marine Calcium Reagent - 25 tests |
| HI-764‑25 | Marine Nitrite ULR Reagent - 25 tests |
| HI-772‑26 | Marine Alkalinity Reagent - 25 tests |
| HI-774‑25 | Marine Phosphate ULR Reagent - 25 tests |
| HI-780‑25 | Marine pH Reagent - approximately 100 tests |
| HI-781‑25 | Marine Nitrate LR Reagent - 25 tests |
| HI-782‑25 | Marine Nitrate HR Reagent - 25 tests |
| HI-783-25 | Marine Magnesium Reagents - 25 tests |
| HI-784-25 | Marine Ammonia Reagent - 25 tests |
| HI-97105‑11 | CAL Check™ standards for HI-97105 & HI-97115 - cuvette kit |
| Other Accessories | |
| HI-70436M | Deionized water (230 mL) |
| HI-7101419 | Blue carrying case for HI-97115 |
| HI-731318 | Cloth for wiping cuvettes (4 pcs.) |
| HI-731360 | Glass cuvette with cap (2 pcs.) |
| HI-740270 | 10 mL syringe with Luer Lock (1 pc.) |
| HI-740271 | Filter holder with Luer Lock (1 pc.) |
| HI-740272 | 16 gauge blunt needle (6 pcs.) |
| HI-740273 | Marine Nitrate LR measurement kit (1 pc.) |
| HI-740228 | Filter disc (25 pcs) |
| HI-93703‑50 | Cuvette cleaning solution (230 mL) |
(Please note: not all reagents and the Cal Check standard are included in this kit, so check your testing requirements are covered when ordering. See specification table to choose further reagents. Additional costs apply.)
Sikkerhetsdatablad
Sikkerhetsdatablad
Manualer
Manualer
Betalingsinformasjonen din behandles sikkert. Vi lagrer ikke kredittkortopplysninger og har ikke tilgang til din kredittkortinformasjon.