HI-97790C bærbart klorfotometersæt inklusive bæretaske og kalibreringskontrolstandarder
HI-97790C bærbart klorfotometersæt inklusive bæretaske og kalibreringskontrolstandarder
På lager
Det bærbare fotometer HI-97790 måler både frit og samlet klor. Dette meget præcise måleinstrument kan måle hver parameter efter hinanden med én enkelt prøve, hvilket effektiviserer arbejdsgangen og øger testeffektiviteten. Fotometeret er ideelt til pålidelige målinger inden for en række vigtige brancher, herunder vandforsyning, drikkevand og spildevandsbehandling. Sættet er en god måde at komme i gang med fotometeret og CalCheck-standarderne på. Reagenser sælges separat. (Sættets indhold kan afvige fra billedet - se det faktiske indhold nedenfor).
Afhentningstilgængelighed kunne ikke indlæses
Beskrivelse
Beskrivelse
HI-97790C Total and Free Chlorine Portable Photometer Kit
About the photometer:
The HI-97790 Total and Free Chlorine Photometer offers an efficient, accurate way to measure two of the most vital water parameters for the water utility, drinking water and wastewater industries. This portable meter has a built-in successive process for the measurement of free chlorine followed by total chlorine, requiring a single sample to complete both measurements for efficiency in testing. Reagents and extra CalCheck standards for this photometer are sold separately.
This portable water meter is an ideal solution for regulatory and compliance requirements where successive sample measurements are necessary. The HI-97790 can be carried anywhere on-site and in the field for measurement, with a positive-locking system that ensures vials are placed in the same position with each measurement, providing consistency and reliability in testing.
The method is an adaptation of the Standard Methods, 4500‐Cl G, DPD Colorimetric Method.
HI-97790C KIT includes:
- Photometer
- Sample cuvette (2 pcs.)
- Sample cuvette cap (2 pcs.)
- Plastic stopper (2 pcs.)
- A ZERO - CAL Check™ cuvette A
- HI-97701B - CAL Check cuvette B for Free and Total Chlorine (powder & liquid)
- Cloth for wiping cuvettes
- Scissors
- 1.5V AA alkaline battery (3 pcs.)
- CAL Check standard certificate
- Quick reference guide with instructions for manual download and instrument quality certificate
- HI-7101412 rigid carrying case
- Please note: Reagents are sold separately
Speak to our experts about our water quality measurement instruments today. Call us on 01525 850855 or email us at sales@hannainstruments.co.uk
HI-97790 Features
One sample, two measurements
The HI-97790 allows you to perform successive measurements of free and total chlorine using a single sample. This saves time and improves efficiency in testing while meeting regulatory compliance where measurement of both using a singular sample is required. These are the steps to measure free and total chlorine with this compact portable photometer:
- Take a zero reading
- Add required reagents for free chlorine measurement
- Read the results of testing
- Add required reagents for total chlorine measurement
- Read the results of testing
- Dispose of your sample
Measure anywhere
The portable design of the HI-97790 allows this water photometer to be utilised in a wide range of environments where free and total chlorine measurements are required. The photometer uses AA batteries, with no requirement for connection to power to complete measurement. A built-in battery status indicator provides clear information about the remaining battery life, with auto shut-off to prevent battery wastage.
Designed for ease of use
The HI-97790 Free and Total Chlorine Photometer includes multiple features for ease of use when measuring. Auto data log records the results of testing, with the ability to recall up to 50 individual measurements from the meter for immediate comparison. The unit of measurement is displayed on the screen with the reading, and a robust error system prevents incorrect measurement due to no cap, high zero and standard too low.
On-screen tutorial mode
A complete on-screen tutorial provides step-by-step instructions for the measurement process, making it easy to accurately and consistently test water samples. This tutorial can be used at any time and is easily accessible on the photometer, with no additional software or connection required.
Advanced optical design
The HI-97790 features an advanced LED optical system that utilises a reference detector and a focusing lens to eliminate errors typically caused by changes in light source or imperfections within glass vials. The use of LEDs provides more light while reducing the amount of power required for each test and emits little heat to ensure long-term electronic stability.
The system is sealed to prevent dust, dirt or water from entering. A positive-locking system for the inserted vials ensures they are placed in the same position each time for consistently accurate measurement in combination with the LED optical system.
Built-in timer
This photometer for chlorine includes a built-in reaction timer, helping to ensure consistency between both individual and successive tests. The timer is displayed clearly on the screen, providing feedback during the testing process.
Cal Check included
Validate the performance of the HI-97790 at any time with Cal Check vials made with NIST traceable standards. The Cal Check screen provides clear step-by-step instructions for the validation process and user calibration, for peace of mind during measurement.
Floating case for easy retrieval
The HI-97790 features a waterproof IP67-rated case, ensuring this instrument can continue operation after it is dropped in water. This meter also floats on the surface, allowing for easy retrieval in the field. The robust design of this meter makes it suitable for measurement in a wide range of environments.
FAQs
What industries is the HI-97790 suitable for?
The HI-97790 chlorine water photometer is suitable for a range of different industries. The primary applications for this meter include drinking water and wastewater measurement. This compact meter is also suitable for the measurement of free and total chlorine in swimming pools and hot tubs.
Can this chlorine meter measure both types of chlorine?
This compact portable photometer measures both free and total chlorine. Only a single sample is needed to measure both parameters in succession, providing an easy and efficient method to determine both the free and total chlorine levels within your sample.
Can you access data directly on the HI-97790?
Automatic logging functionality stores data directly in the HI-97790 meter for ease of access. Once data has been logged, up to 50 individual measurements can be recalled using the menu on the meter, enabling access to earlier information for recording and comparison.
Which reagents do I need for the HI-97790?
This chlorine photometer is compatible with the following reagents:
- HI-93701-F free chlorine liquid reagent for 300 tests
- HI-93701-T total chlorine liquid reagent for 300 tests
Order these reagents and Cal Check standards online today, with next-day delivery for all solutions in stock.
Can I get a demonstration of the HI-97790?
If you’d like to learn more about the HI-97790, speak to our experts directly. Our in-house team can provide professional advice and guidance on our range of water testing instrumentation, helping you to find the best solution for your requirements and regulatory standards. Call us on 01525 850855 or email us at sales@hannainstruments.co.uk.
Where can I buy the HI-97790 chlorine photometer?
You can buy our free and total chlorine photometer online today, with free next-day delivery for products that are in stock. If you would like advice on Hanna’s wide range of products for wastewater, drinking water, water utilities or swimming pools, get in contact with our team directly at 01525 850855 or email us at sales@hannainstruments.co.uk.
Specifikationer
Specifikationer
| Range | 0.00 to 5.00 mg/L (as Cl₂) | |
| Resolution | 0.01 mg/L | |
| Accuracy | ±0.03 mg/L ±3% of reading at 25 °C | |
| Method | Adaptation of Standard Methods, 4500-Cl G, DPD Colorimetric Method | |
| Light source | Light emitting diode | |
| Bandpass filter | 525 nm | |
| Bandpass filter bandwidth | 8 nm | |
| Bandpass filter wavelength accuracy | ±1.0 nm | |
| Light Detector | Silicon photocell | |
| Cuvette type | Round 24.6 mm diameter (22 mm inside) | |
| Auto logging | 50 readings | |
| Display | 128 x 64 pixel B/W LCD with backlight | |
| Auto-off | After 15 minutes of inactivity ((30 minutes before a Free Cl2 / Total Cl2 measurement) | |
| Battery type | Alkaline 1.5 V AA (3) | |
| Battery Life | above 800 measurements (without backlight) | |
| Environment | 0 to 50 °C (32 to 122 °F); 0 to 100% RH, non-serviceable | |
| Dimensions | 142.5 x 102.5 x 50.5 mm (5.6 x 4.0 x 2.0") | |
| Weight | 380 g (13.4 oz.); with batteries | |
| Casing | IP67, floating case | |
| Additional information: | HI-97790C is supplied withPhotometerSample cuvette (2 pcs.)Sample cuvette cap (2 pcs.)Plastic stopper (2 pcs.)A ZERO - CAL Check™ cuvette AHI-97701B - CAL Check cuvette B for Free and Total Chlorine (powder & liquid)Cloth for wiping cuvettesScissors1.5V AA alkaline battery (3 pcs.)CAL Check standard certificateQuick reference guide with instructions for manual download and instrument quality certificateHI-7101412 rigid carrying casePlease note: Reagents are sold separately |
Sikkerhedsdatablad
Sikkerhedsdatablad
Du kan finde sikkerhedsdatablade for vores produkter her
Manualer