HI-88703-02 Bench Top Turbidity Meter, EPA Compliant
HI-88703-02 Bench Top Turbidity Meter, EPA Compliant
Pris ekskl. mva.
In stock
Hanna HI-88703-02 Bench Top Turbidity Meter (EPA Compliant) is a high-precision laboratory instrument designed for turbidity measurement in accordance with EPA methods. It provides accurate and reliable readings, particularly at low turbidity levels, making it ideal for drinking water and regulatory compliance testing.
Featuring an advanced optical system and intuitive operation, the HI-88703-02 ensures consistent, reproducible results in laboratory environments where accuracy and traceability are critical.
Key Features
- EPA compliant turbidity measurement
- High accuracy at low turbidity levels
- Advanced optical system for reliable readings
- Fast and easy calibration with standards
- GLP data for traceability and documentation
- Clear display with user-friendly interface
- USB connectivity for data transfer
Applications
- Drinking water testing
- Regulatory and compliance laboratories
- Environmental water analysis
- Wastewater monitoring
- Industrial water quality control
What's Included
- HI-88703-02 turbidity meter
- Calibration standards
- Sample cuvettes with caps
- Cleaning cloth
- USB cable
- Power adapter
- Instruction manual
Measurement Method
The instrument uses a nephelometric method in accordance with EPA standards. Turbidity is determined by measuring the intensity of light scattered by suspended particles in the sample, providing accurate results especially in low turbidity ranges.
Why Choose HI-88703-02?
- Meets EPA requirements for regulatory testing
- Excellent performance in low turbidity applications
- Reliable and reproducible laboratory results
- Essential tool for compliance and quality assurance
Couldn't load pickup availability
Description
Description
The HI-88703-02 turbidity bench top meter is specially designed for water quality measurements, providing reliable and accurate readings on low turbidity ranges.
This instrument has an EPA compliance reading mode which rounds the reading to meet EPA reporting requirements. Depending on the measured sample and needed accuracy, normal, continuous or signal averaging measurement can be selected.
A two, three, four or five-point calibration can be performed. When user prepared standards are used, calibration points can be modified. The HI-88703-02 features complete GLP (Good Laboratory Practice) functions that allow traceability of the calibration conditions. The last calibration points, time and date can be checked. Up to 200 measurements can be stored in internal memory. Data can be transferred to a PC via optional HI-920013 USB cable and HI-92000 Windows® compatible software.
The HI-88703-02 meets and exceeds the requirements of USEPA and Standard Methods.
Key features
- Two measuring ranges: Ratio turbidity, non-ratio turbidity
- GLP features
- Two, three, four or five point turbidity calibration
- USB PC connectivity
- Log up to 200 measurements
- Contextual help and tutorial mode
Order information
The HI-88703-02 is supplied with sample cuvettes and caps (5), calibration cuvettes, silicone oil (HI-93703-58), tissue for wiping cuvettes, power cord and instruction manual.
PC Interface - Download test results to a computer programmed with HANNA’s Windows® compatible software directly from equipment via a USB port or a RS232 cable outlet.