HI-93713-01 Phosphate Low Range Reagents – 100 Tests
HI-93713-01 Phosphate Low Range Reagents – 100 Tests
Hurry up, only 4 items left in stock.
The Hanna HI-93713-01 contains pre-measured powder reagents for the photometric determination of low-range phosphate in water. Designed for use with compatible Hanna portable and benchtop photometers, these reagents are suitable for drinking water analysis, wastewater monitoring, environmental testing and routine water quality control.
Using an adaptation of the ascorbic acid method, the reagent reacts with phosphate in the sample to produce a blue colour. The photometer measures the colour intensity and calculates the phosphate concentration, displaying the result in mg/L (ppm).
Each sachet contains a precisely measured quantity of reagent, simplifying sample preparation and helping ensure consistent measurements. Individual packets are marked with a lot number and expiry date for improved traceability.
The pack provides reagents for 100 tests, making it a convenient choice for laboratories and water professionals carrying out regular phosphate analysis.
Couldn't load pickup availability
Description
Description
The HI-93713-01 are high quality reagents that are pre-measured, allowing for users to achieve fast and accurate colorimetric measurements. The method is an adaptation of the ascorbic acid method in which the reaction between phosphate and the reagent causes a blue tint in the sample. The intensity of colour is determined by a compatible photometer and the phosphate concentration will be displayed in mg/L (ppm). These reagents are designed to be used with samples that have an expected range of 0.00 to 2.50 mg/L (ppm) phosphate.
This reagent provides enough to do 100 tests.
Tip for an accurate measurement
It is important that the sample does not contain any debris.
When the cuvette is placed into the measurement cell, it must be dry outside and completely free of fingerprints, oil or dirt. Wipe it thoroughly with HI-731318 or a lint-free cloth prior to insertion.
Shaking the cuvette can generate bubbles, causing higher readings. To obtain accurate measurements, remove such bubbles by swirling or by gently tapping the cuvette.
Do not let the reacted sample stand for too long after reagent is added, or accuracy will be lost.
After the reading, it is important to discard the sample immediately, otherwise the glass might become permanently stained.