HI-943500B Conductivity Controller (High Range @ 19.99 mS/cm)
HI-943500B Conductivity Controller (High Range @ 19.99 mS/cm)
Price excludes VAT.
In stock
HI-943500 are panel-mounted conductivity controllers designed for simplicity of use in a wide range of industrial process applications. Four different models are available with different measurement ranges, to satisfy any application requirements.
Couldn't load pickup availability
Description
Description
The controller allows the direct connection of a potentiometric conductivity probe (HI 7638) with a cable up to 20 meters long, without using any transmitter.
- Automatic temperature compensation ensures fast, accurately compensated readings even during sudden temperature fluctuations
- Four different models are available with different measurement ranges
- Displays values on the easy to read LCD with backlighting
Four different models are available with different measurement ranges, to satisfy any application requirements.
The output configuration for connecting a recorder or a PLC can be chosen between 0-20 or 4-20 mA.
The LED on the front panel indicates the operating status of the controller.
The automatic temperature compensation (ATC) is performed directly by the HI-7638 probe with built-in temperature sensor.
The front panel is protected behind a transparent splash-proof cover.
Order Information:
The HI-943500 series is supplied with mounting brackets and instructions.
- HI-943500A: 0.0 to 199.9 mS/cm
- HI-943500B: 0.00 to 19.99 mS/cm
- HI-943500C: 0 to 1999 µS/cm
- HI-943500D: 0.0 to 199.9 µS/cm
| Range | 0.0 to 19.99 mS/cm | |
| Resolution | 0.01 mS/cm | |
| Accuracy | ±2% F.S. | |
| Temperature Compensation | automatic, 0 to 60°C (32 to 140°F), with ß=2%/°C | |
| Recorder Output | 4-20 mA (isolated) | |
| Setpoint Relay | 1, isolated, 2A, Max. 240 V, resistive load, 1,000,000 strokes | |
| Alarm Relay | 1, isolated, 2A, Max. 240 V, resistive load, 1,000,000 strokes | |
| Power Supply | 115/230 ±10% Vac; 50/60 Hz | |
| Enclosure | black anodised aluminium body; front and back with ABS; transparent splash-proof front cover |
|
| Environment | -10 to 50°C (4 to 122°F); RH max 95% non condensing | |
| Panel Cutout | 141 x 69 mm (5.6 x 2.7") | |
| Weight | 1 kg (2.2 lb.) |
Specifications
Specifications
| Range | 0.0 to 19.99 mS/cm | |
| Resolution | 0.01 mS/cm | |
| Accuracy | ±2% F.S. | |
| Temperature Compensation | automatic, 0 to 60°C (32 to 140°F), with ß=2%/°C | |
| Recorder Output | 4-20 mA (isolated) | |
| Setpoint Relay | 1, isolated, 2A, Max. 240 V, resistive load, 1,000,000 strokes | |
| Alarm Relay | 1, isolated, 2A, Max. 240 V, resistive load, 1,000,000 strokes | |
| Power Supply | 115/230 ±10% Vac; 50/60 Hz | |
| Enclosure | black anodised aluminium body; front and back with ABS; transparent splash-proof front cover | |
| Environment | -10 to 50°C (4 to 122°F); RH max 95% non condensing | |
| Panel Cutout | 141 x 69 mm (5.6 x 2.7") | |
| Weight | 1 kg (2.2 lb.) |